A walkthrough of the Display Safety Record, with a fillable form to download and a worked sample show to read.

The Display Safety Record, or DSR, is the paperwork that shows you thought about the hazards, chose controls and checked them. The Standard (AS/NZS IEC 60825.3:2022) lists what it should hold in clause 7.5, as items a to k. If something goes wrong, a regulator, an insurer or the venue will ask to see it. You keep it at the show site and update it at every stage, from design to dismantling.

You do not need to start from a blank page. The files above help. The fillable form follows the Standard's list in order and has typical entries filled in. The sample is a finished record for a made-up show, so you can see how much detail a reviewer expects. You can read it as a PDF or take the Word version as a layout. Do not copy values from either one. Measure and assess your own show.

Start with the show: the equipment, the venue layout and the effects. List each projector with its label, model, serial number, class and mounting position. Add a plan view and a side view that show where the beams go and where people are. Then give the beam details from the maker's manual: power for each colour, wavelength, divergence, scan rates, and the scan-fail safeguard with its measured response time. [items a, b, c, i]

Next come the risk assessment and the controls. Do not write a long list of hazards. Go through each stage, from design to dismantling, and note the main hazards, who could be reached and the controls you chose. Give the reason for every control. A projector 5.5 metres above the floor and a physical mask below horizontal are strong controls, because they still work if something fails. Signs and briefings help, but they are weaker, so say what backs them up. [items d, e]

The separation and exposure sections are where you show your numbers. Measure the lowest beam above every place people stand, and compare it with the distances in the Standard. If you scan the audience, these sections grow a lot. You need the spectator limit, fast peak-power measurements, the instrument and its set-up, and the scan-fail tests. Reviewers read that part most closely. If you do not scan the audience, say so, and explain why position and masks keep you under the limit. [items j, k]

Then cover the people and the emergencies. Name the designer, installer, operator, laser safety officer and equipment owner, with phone numbers. Write a contingency plan with specific steps. The Standard's plan covers three cases: an actual eye injury, an actual skin injury, and an exposure above the limit that could have injured an eye. In every case the first step is to end the emission. Add the hospital, the venue contact and the emergency number. [items f, g, cl. 7.6]

Record your approvals and restrictions too. These are the state radiation regulator, work health and safety, aviation, maritime, the council and the venue. The rules differ by state and change over time, so get each answer in writing and keep it with the record. [item h]

Last, keep the check records. They hold the pre-show checks of masks, e-stops, mounts and signs, the alignment record and a show log. Every incident goes in the log. The results start empty on purpose, because a record may show only checks that were actually done. A checklist is not magic, so also ask what is different tonight. [cl. 7.3.7, 7.4.6, 8.2.7]

The common mistakes are easy to avoid. People copy values from a template. They write 'high enough' instead of a measurement. They treat the scan-fail safeguard as the main control, when it is only a backup. And they leave the contingency plan vague. Write the first version before you arrive, then update it after the venue visit. Number each revision and keep the old ones. The Standard sets no retention period, so ask your regulator and insurer how long they expect records to be kept.