Assessing a Venue
What to measure, check and photograph when you visit a venue before a laser show.
Visit the venue before you finalise the design. Drawings are often out of date, and they never show the shiny things. You want to stand in the room and see where the projector can go, where people will be, and where every beam will end. If the venue will not let you visit, ask for photos and measurements, and plan to check everything again at bump-in.
Bring a laser distance meter, because a tape does not reach the ceiling. Measure the ceiling height over the stage and over the audience. Then measure the lowest thing hanging below it, such as a truss, an air conditioning duct or a speaker. Note every rigging point you might use, and ask the venue what load each one can take. Ask who is allowed to rig, because many venues insist on their own riggers.
Next, find every place a spectator can stand or sit. That means balconies, raised platforms and tiered seating, not only the main floor. The Standard (AS/NZS IEC 60825.3:2022) measures the separation from each of those surfaces. With an operator in continuous control, beams above the spectator limit stay at least 3 metres above any surface where people can stand, and at least 2.5 metres away to the side. A platform 1.5 metres high lifts the lowest allowed beam by 1.5 metres over that platform. Without an operator in continuous control, the vertical distance rises to 6 metres. [cl. 6.10, 6.12]
Look for anything that could send a beam somewhere it should not go. That includes mirrors, mirror balls, polished metal, chrome, glass partitions, glossy bar tops and wet or shiny floors. Think about what people bring too, such as foil banners and reflective balloons. Venues change their decorations between visits, so look again at bump-in and once more before the doors open. [cl. 7.3.7, 7.3.11]
Now think about the people who are not in the audience. Bar staff, security, caterers and cleaners move around the room all night. They have no eyewear, and nobody controls where they walk. Note the doors they use and the places they stand, and ask whether any of them pass through a beam area. Check the emergency exits as well. Your equipment and your beams must never block them. [cl. 5.4, 7.2.2]
Cover the practical questions while you are there. Where will the power come from? Where can the control position go, with a clear view of every projection? Will the smoke or heat detectors react to haze? Who is the venue contact on the night, and who holds the keys? How far is the nearest hospital emergency department? Each answer goes into your Display Safety Record.
Take photos and write down numbers. 'The projector is high enough' means nothing to a reviewer. '5.5 metres on the stage truss, with the lowest beam 5.5 metres above the floor at the barrier' does. Draw a plan view and a side view showing the projector, the beams, the audience, the barrier and the exits. The Standard asks for both drawings. Keep your notes, because they save hours if you come back to the same venue. [cl. 7.2.2]
Want to learn more? The LSO Certification course covers this topic in depth with interactive exercises, quizzes, and a final exam. Module 1 is free to preview.